15
Years in the fire service
100%
Firefighter technicians
BBB
Accredited business
CPO
Certified owner
Where faults hide
The water usually tells you before the equipment does
Cloudy water that will not clear, a sanitizer level that will not hold, or a pool that goes green in the same week every year are all commonly equipment problems wearing a chemistry costume.
Chasing them with product is expensive and does not work. A dirty filter, a tired pump or a scaled salt cell will keep undoing whatever you add.
- Filter pressure high, or flow low with clean baskets
- Pump whining, rattling, short-cycling or running hot
- Heater that lights and drops out, or will not light
- Salt cell reporting output the water does not show
- Automation out of step with what the equipment is doing
Automation and electrical
Half of what looks mechanical is wiring
Control systems fail quietly. A flow switch, a relay or a corroded terminal will make an otherwise healthy pump or heater behave like a broken one, and the panel will happily report that everything is fine.
We open the panel and check it rather than reading the screen and believing it.
- Panels, relays, breakers and bonding
- Flow switches and sensors that report the wrong state
- Automation settings left where last season put them
By equipment
Pages for the two we are asked about most
Heater and pump work have their own pages. Everything else on the pad is covered here.
-
A heater that lights and stays lit
Ignition, gas, boards and the electrical behind them, on pool and spa heaters.
-
A pump that runs quietly and moves water
Motors, seals, capacitors, impellers and the plumbing either side of them.
Questions
What people ask about equipment
What counts as equipment?
Everything on the pad and the wiring that reaches it: filter, pump, heater, chlorinator or salt cell, valves, automation, panels and bonding. If it is between the breaker and the water, it is ours.
How do I know something is starting to fail?
Filter pressure climbing and staying high, flow that has dropped without the baskets being full, a pump that whines or short-cycles, or automation that reports a state the equipment is plainly not in. Any of those is worth a look before it stops entirely.
My salt system says it is producing chlorine but the water tests at zero.
That is common and usually not the cell lying. A scaled cell, low salt, poor flow, a failed flow switch, cold water or an output setting left at a spring level will each produce it. We check the cell, the flow and the settings rather than replacing the cell first.
Do you replace equipment as well as repair it?
Yes, and we will tell you which one we think you should do. Where a repair is close to the cost of a replacement we say so, and the choice is yours.
Is the electrical work part of the same visit?
Pool electrical is, and it is often the actual fault. Work belonging to the house rather than the pool goes to an electrician and we will tell you plainly which side of that line your problem is on.
Request service
Tell us what the equipment is doing
The noise, the reading or the thing that stopped is enough to start with. We will call you back on the number you leave.
Rather talk it through? (408) 316-8425